Menu
Your Cart

Contec Handle Pulse Oximeter CMS60D

Contec Handle Pulse Oximeter CMS60D
Contec Handle Pulse Oximeter CMS60D
Contec Handle Pulse Oximeter CMS60D
Free shipping
Contec Handle Pulse Oximeter CMS60D
Contec Handle Pulse Oximeter CMS60D
Contec Handle Pulse Oximeter CMS60D
Contec Handle Pulse Oximeter CMS60D

Contec Handle Pulse Oximeter CMS60D, human oxygen saturation and pulse rate can be measured with the integrated Capacity Pulse Scanning and Recording Technology that adopts Photoelectric Oxyhemoglobin Inspection Technology for fingertip use. The device is suitable for use in family, hospital, oxygen bar, community health, and physical care in sports, etc. (It can be used before or after exercise, but it is not recommended to be used during exercise).

 

Hemoglobin saturation is the percentage of the volume of all combinable Hemoglobin (Hb) in the blood, through which Oxygenated Hemoglobin (HbO2) combines with oxygen, in other words, it is the density of Oxygenated Hemoglobin in the blood. It is an important ecological parameter for the Respiratory Circulation System. Many respiratory diseases can result from a decrease in Hemoglobin Saturation in the blood. In addition, factors such as Anesthesia, Intensive Postoperative Trauma, injuries resulting from certain medical tests, etc., can cause problems in the oxygen supply, leading to a decrease in hemoglobin saturation. In these cases, the patient may experience mild symptoms such as headache, weakness, vomiting, etc., and it may jeopardize the patient's life. For these reasons, it is crucial to know the patient's Hemoglobin Saturation in a timely manner in clinical medical situations, so that doctors can diagnose the problem in a timely manner.

 

The Color TFT Pulse Oximeter device is small, requires very little power, and is convenient for use and portability. It is sufficient to place the patient's fingertip on the finger-type photoelectric sensor of the device for diagnosis, and the measured Hemoglobin Saturation will be displayed directly on the screen. The high precision and repeatability feature of the device has been proven in clinical practice. To ensure accuracy and suitability, our company has developed the Color TFT screen pulse oximeter, and the device also accurately tests the pulse rate. The device also has a 24-hour storage memory, real-time data, and data transfer capabilities. The device is small, inexpensive, easy to use, and portable. When you open the device, during the test, it is sufficient to place your finger on the probe, and the SpO2 value will be displayed directly on the screen. During the actual test, when the hematoid field is between 70% and 100%, the test error is below ±2%.

 

Specifications:

 

- Accurately tests SpO2 and Pulse Rate.

- Displays on a 160*128 TFT color LCD screen.

- Low power consumption, continuous operation for 24 hours with a 1000mAh lithium battery configuration.

- Automatic shutdown with power indicator and low power alarm when running on low power.

- The device is rechargeable, and the charging time is less than 6 hours.

- Has a 24-hour data memory.

- Data can be transferred to a computer.

- The device is small in volume, lightweight (approximately 215g including the battery), and easy to carry.

- Product Class: Class II a BF category (according to MDD Annex IX, Rule 10).

 

Display Format: Wide TFT Color LCD screen SpO2: 35%-99%. Pulse Rate: 30-240BPM. Pulse Wave Display: Continuous bar graph display and wave display. Battery Power Indicator: TFT sign. Power Requirements: Rechargeable Lithium Battery, voltage range: 3.6-4.2 V. Power Consumption: Less than 0.15VA. Transmission electric current: Less than 50mA. Optical transducer: bright (length 660nm), infrared ray (length 905nm) Resolution: 1% for Hemoglobin Saturation and 1 BPM for Pulse Rate. Measurement Accuracy: ±2% in stages where Hemoglobin Saturation is between 70%-100%, undefined in stages below 70%. ±2 BPM for Pulse Rate. Measurement Performance in Full Movement: Oxyhemoglobin and pulse value can be displayed correctly only when the pulse filling rate is 0.4%. Environmental Noise Resistance Capacity: The deviation between the measured Oxyhemoglobin value under natural lighting conditions in indoor settings and the measured Oxyhemoglobin value under available lighting sources in a dark room is ±1%. Data transfer rate: 19200bps. Power button is used to turn the device on and off.

Basic Features
ManufacturerContec
TürOximeter

Write a review

Please login or register to review

Önemli Not

* Yapı Kredi Bankası için vade tutarları ortalama değerlerdir, ödeme adımında değişkenlik gösterebilir.

* Bazı vade tutarları ortalama değerlerdir, ödeme adımında ürünlerin KDV’lerinin farklılıklarından dolayı değişkenlik gösterebilir.

* Ödeme esnasında erteleme işlemi seçilen taksitlerde vade farkından dolayı tutar farklılıkları görülebilir.

3 Installments for Cash Price!
%7 Havale İndirimi ile 6.917,34 TL
7,438.00 TL
  • Stock: In Stock
  • Model CMS60D
Add to Cart
PAZARTESİ KARGODA! PAZARTESİ KARGODA!